CASE
CASE

Marine external fire fighting system

The marine external fire-fighting system is widely used as a tugboat, full-time fire-fighting boat and offshore platform supply ship in inland rivers and coastal ports. It is a professional fire-fightingsystem for external fire-fighting of ships.



The marine external fire-fighting system is widely used as a tugboat, full-time fire-fighting boat and offshore platform supply ship in inland rivers and coastal ports. It is a professional fire-fightingsystem for external fire-fighting of ships.

 

The marine External Fire- fighting System provides three levels of FiFi-I, FiFi-ll and FiFi-Ill Based on the technical advantages of our fire-fighting water monitors and pump sets, with a more compact and stable product structure and a wider flow range and more concentrated water column range, combined with the cable and wireless electrical control system independently developed by the Company, which is a well-known product in the field of global marine External Fire-fighting Systems.

 

Equipment Type of External Fire-fighting System
I II
Minimum number of water monitors 2 3 4 4
Minimum discharge rate of each water monitor (m³/h) 1200 2400 1800 2400
Minimum number of fire-fighting pumps 1 2 2
Minimum total capacity of fire-fighting pump(m³/h) 2400 7200 9600
Performance of water monitor      
Minimum height of watermonitorjettrajectoryabovewatersurface(m) 45 70 70
Minimum range of water monitor (m) 120 150 150
Minimum duration of fuel required for simultaneous and continuous operation of all water monitors (H)  24 96 96
Fixed  Foam  System:      
Minimum number of foam monitors   2
Minimum discharge rate of each foam monitor(m³/h)   300
Continuous foam generation time(min)   30
Portable fire-fighting equipment:      
Portable foam generator      
Minimum foam  supply rate(m³/min) 100 100
Continuous foam generation time(min)  30  30
Fire hose      
Number of fire-fighting hose hydrants and connectors on each side of the ship  4 8  8
Equipment for firemen  4 8  8